防火阻燃测试--中国防火网 400-603-6575

中国防火网专注于英国防火测试BS6853,法国防火测试NFF16-101,德国防火测试DIN5510-2,美国防火测试NFPA130,欧标EN45545等防火阻燃测试

建筑材料阻燃等级有E级吗

欧盟建筑产品的防火阻燃等级被划分为七个等级:A1、A2、B、C、D、E、F。所在在欧盟市场上生产、销售、流通的建筑产品及材料的防火等级必须至少达到EN13501-1中的E级。防火等级E级是建材防火的最基本等级。南京睿督公司与大家分享EN13501-1标准E级规定及测试内容,咨询电话:025-8658 3475。

EN13501-1防火等级E级测试标准及数据要求:
EN13501-1防火等级:根据EN ISO 11925-2标准进行测试并且同时符合要求。
...

巴黎大众运输公司RATP

巴黎RATP公司(Regie Autonome dea Transports Parisiens),巴黎地铁现由巴黎大众运输公司(RATP)负责营运。在八十年代,RATP和SNCF制定法国标准:NF F16-101和NFF16-102,这份在1998年版本出具的NFF16-101法国轨道车辆的标准一直引用至今。两个法国公司对上述标准描述中塑料燃烧性能方面的许多发展做出了积极的贡献。咨询电话:025-8658 3475。

RATP实验室为法国COFRAC法国认可委员会认可的实验室。RATP具有法国和国际多种资质。许多厂商都十分信任RATP出具的测试报告及证书。中国防火网携手RATP实验室为广大客户提供法国COFRAC资质NFF16-101测试报告及证书,咨询电话:400-666-7290。

...

ASTM C612隔热矿棉测试标准

ASTM C612 Standard Specification for Mineral Fiber Block and Board Thermal Insulation
ASTM C612 隔热的矿物纤维块材和板材标准规范

This specification covers mineral fiber block and board thermal insulation. Mineral fiber board insulation covered by this specification shall be classified into types and categories; category 1 - no compressive resistance properties are required, category 2 - minimum compressive resistance properties are required, type V, grade A - requires no heat-up schedule, type V, grade B - heat-up schedule is required. Mineral fiber block and semi-rigid and rigid board insulation shall be composed of rock, slag, or glass processed from the molten state into fibrous form and bonded with organic or inorganic binders or both. A detectable odor of objectionable nature recorded by more than two of five panel members shall constitute rejection. When tested and evaluated, the corrosion resulting from insulation in contact with steel plates shall be judged to be no greater than for comparative plates in contact with sterile cotton. When tested and evaluated at its delivered thickness, all mineral fiber (rock, slag, and glass) board and block must qualify to be semi-rigid or rigid. When tested, the board and block insulation shall not warp, flame, or glow during hot surface exposure. When tested, the midpoint temperature shall not at any time exceed the hot surface temperature by more than 200°F (111°C). Determine the thermal conductivity as a function of temperature for the representative specimens with data obtained from a series of thermal tests. The compressive resistance, linear shrinkage, water vapour sorption, odor emission, and rigidity or semi-rigidity shall be tested to meet the requirements prescribed.
...

ASTM C553商用和工业用矿物纤维毡隔热的标准规范

ASTM C553 Standard Specification for Mineral Fiber Blanket Thermal Insulation for Commercial and Industrial Applications
ASTM C553 商用和工业用矿物纤维毡隔热的标准规范

This specification covers the classification, composition, physical properties, and dimensions of mineral fiber (rock, slag, or glass) blanket intended for use as thermal insulation on surfaces at certain temperatures. The orientation of the fibers within the blanket is primarily parallel to the principal surface (face). The mineral fiber blanket insulation shall be classified into seven types: Types I, II, III, IV, V, VI, and VII. The classification is based upon the insulations' maximum use temperature and apparent thermal conductivity. Mineral fiber blanket insulation shall be composed of rock, slag, or glass processed from the molten state into fibrous form bonded with an organic or inorganic binder, or both. Asbestos shall not be used as an ingredient or component part of the product. Different test methods shall be performed on the insulation to determine the following properties: odor emission, corrosiveness to steel, non-fibrous content, maximum use temperature, maximum exothermic temperature rise, apparent thermal conductivity, water vapor sorption, flexibility, rigidity, and surface burning characteristics.

...