Home station  
Set as homepage Add to favorites    中文版 繁体 English
 
Testing to: Rolling Fire testing | Building Fire testing | Marine material | Aircraft material | Fire Resistance | Jet Fire | Other
   
User name:
Password:
Code:
   
Fire standard
RailwayMarineBusBuilding
Test method More>>
BS 476-6:1989+A1:2009 fire...
BS 476-7:1997 Classificati...
BS 476-20:1987 fire resist...
BS ISO 4589-2:2006-06
NF P 92-501: M classificat...
NF P 92-503: M classificat...
NF P 92-504: Speed of spre...
ASTM E 662: Smoke density ...
ASTM E 648 Flooring test
ASTM E 162: surface flamma...
 
Home   Train   BS 6853:1999 British Standard
 

BS 6853:1999 British Standard

British Standard BS 6853:1999

 

1. Standard-- BS 6853:1999 Fire testing to railway components

BS6853:1999 Code of practice for fire precautions in the design and construction of passenger carrying trains

 

2. Standard Brief-- BS 6853:1999 Fire testing to railway components

The aim of this standard is to ensure the safety of passengers in the event of fire on or around a vehicle or vehicles comprising a passenger carrying train. The standard has been extensively revised to assist railway vehicle builders in interpreting guidance from the Safety Regulatory Authority on fire performance previous edition and reflects the concern of Fire Standards Committee by upgrading the responsibilities of railway vehicle designers, builders and manufacturers, encouraging them to produce safer materials which release less toxic effluent in a fire, for future safety.

 

Thus adherence to the code should be considered to have provided an environment for which it has been demonstrated that:

--acceptable control of the risk of ignition has been achieved;

--acceptable control of the rate of and total emission of heat, smoke and toxic fume has been achieved for all major usage materials and surfaces when exposed to a source of ignition;

--acceptable resistance to fire has been achieved for all materials and items required to perform as a barrier to fire or which are required to perform some function when exposed to fire.

 

3. Classification of vehicle categories-- BS 6853:1999

There are two main classes of operating environment which are designated as follows

Category : a and b (underground)

Category: surface

Category a: Substantial operating periods in single track tunnel with no side exits to a walkway and escape shafts, or sleeper vehicle which operate underground for significant periods, or trains that operate without staff.

Category b: Substantial operating periods in a multi-track tunnel, or a tunnel with side exits to walkway and escape shafts or sleeper vehicles which do not operate underground for significant periods.

Category: Surface stock with no substantial operating periods in tunnels.

 

4. according to end-use, materials and product testing in according with the following standard:

Test item

End-Use

Required Test

Test method

Specimen required

BS 6853:1999 Table 1

Interior horizontal supine surfaces

Surface spread of  flame or

Critical radiant flux at extinguishment

BS 476-7 or

BS ISO 9239-1

885mm*267mm

1050mm*230mm

Smoke density (Flooring test)

BS 6853:1999 Annex D

600mm*600mm

Toxicity test

BS 6853:1999 Annex B

75mm*75mm

BS 6853:1999 Table 2

Interior vertical surface

Fire propagation

BS 476-6

225mm*225mm

Surface spread of  flame

BS 476-7

885mm*267mm

Smoke density (Panel  test)

BS 6853:1999 Annex D

1000mm*500mm

Toxicity test

BS 6853:1999 Annex B

75mm*75mm

BS 6853:1999  Table 3

Interior horizontal prone surfaces

Fire propagation

BS 476-6

225mm*225mm

Surface spread of  flame

BS 476-7

885mm*267mm

Smoke density (Panel  test)

BS 6853:1999 Annex D

1000mm*500mm

Toxicity test

BS 6853 Annex B

75mm*75mm

BS 6853:1999 Table 4

Exterior horizontal supine surfaces

Surface spread of  flame or

Critical radiant flux at extinguishment

BS 476-7 or

BS ISO 9239-1

885mm*267mm

1050mm*230mm

Smoke density (Flooring test)

BS 6853 Annex D

600mm*600mm

Toxicity test

BS 6853:1999 Annex B

75mm*75mm

BS 6853:1999 Table 5

Exterior vertical surfaces

Surface spread of  flame

BS 476-7

885mm*267mm

Smoke density (Panel  test)

BS 6853:1999 Annex D

1000mm*500mm

Toxicity test

BS 6853:1999 Annex B

75mm*75mm

BS 6853:1999  Table 6

Exterior horizontal prone surfaces

Surface spread of  flame

BS 476-7

885mm*267mm

Smoke density (Panel  test)

BS 6853:1999 Annex D

1000mm*500mm

Toxicity test

BS 6853:1999 Annex B

75mm*75mm

BS 6853:1999  Table 7

Interior minor use materials of mass100gto500g

Oxygen index testing  or

Temperature index testing

BS ISO 4589-2

BS ISO 4589-3

According to sample

Smoke density (small scale test)

BS 6853:1999 Annex D

140mm*60mm*3mm

Toxicity test

BS 6853:1999 Annex B

100g

BS 6853:1999 Table 8

Exterior minor use materials of mass400gto2000g

Oxygen index testing  or

Temperature index testing

BS ISO 4589-2

BS ISO 4589-3

On request

Smoke density (small scale test)

BS 6853:1999 Annex D

140mm*60mm*3mm

Toxicity test

BS 6853:1999 Annex B

100g

BS 6853:1999 Table 9

Seat trim

Back

Fire propagation

BS 476-6

225mm*225mm

Surface spread of  flame

BS 476-7

885mm*267mm

Toxicity test

BS 6853:1999 Annex B<, /P>

75mm*75mm

Base

Surface spread of  flame

BS 476-7

885mm*267mm

Toxicity test

BS 6853:1999 Annex B

75mm*75mm

Assembly

Smoke density (Seating test)

BS 6853:1999 Annex D

400mm*400mm

BS 6853:1999  Table 10

Seat shellback and base

Fire propagation

BS 476-6

225mm*225mm

Surface spread of  flame

BS 476-7

885mm*267mm

Smoke density  (Panel  test)

BS 6853:1999 Annex D

1000mm*500mm

Toxicity test

BS 6853:1999 Annex B

75mm*75mm

BS 6853:1999  Table 11

Textilesfree standing and lying (HS,HP, V surfaces

Burn length

BS 5438

200mm*160mm

Smoke densitysmall scale test

BS 6853:1999 Annex D

140mm*60mm*3mm

Toxicity test

BS 6853:1999 Annex B

100g

BS 6853:1999 Table 12

Mattresses

Surface spread of  flame

BS 476-7

885mm*267mm

Smoke density (Flooring test

BS 6853:1999 Annex D

600mm*600mm

Toxicity test

BS 6853:1999 Annex B

75mm*75mm

BS 6853:1999 Table 13

Interior cable

Burn length

BS 4066-3

On request

Smoke density (Cable test

BS 6853:1999 Annex D

On request

Toxicity test

BS 6853:1999 Annex B

On request

BS 6853:1999 Table 14

Exterior cable

Burn length

BS 4066-3

On request

Smoke density (Cable test

BS 6853:1999 Annex D

On request

Toxicity test

BS 6853:1999 Annex B

On request

 

5. BS 6853:1999 The main fire test standards:

BS 476-6

Method of test for fire propagation for products

BS 476-7

Method of test to determine the classification of the surface spread of flame of products

BS 5438

Methods of test for Flammability of textile fabrics

BS 4589-2

oxygen index Test

BS 4589-3

Temperature Index Test

BS 6853 Annex B

Toxicity

BS 6853 Annex D

Smoke Density Test

BS EN 60332-1-2

Vertical single Cable fire testing

BS EN 50306

Thin thickness of Cable fire testing

BS EN 50264

Standard thickness of Cable fire testing

BS EN 50305

Cable fire testing

BS ISO 5659-2

Toxicity Testing

NF X 70-100

Toxicity Testing

NF X 10-702

Smoke density

BS ISO 9239-1

Radiant panel test for floorings

BS EN 50266-2-4

BS EN 50266-2-5

Vertical bunch Cable fire testing ( diameter≥12mm)

Vertical bunch Cable fire testing ( diameter12mm)

BS EN 50305 sections9.1.1

Vertical bunch Cable fire testing (6mm diameter12mm)

BS EN 50305 sections9.1.2

Vertical bunch Cable fire testing (diameter≤6mm)

 

6. Application BS 6853 Fire testing materials

Rubber ProductRubber seal

Ceiling Covering

Walling Covering

TextileNon-woven fabrics CurtainCurtainAdumbral Product

Seat shellSeat trim

Flooring CoveringPVC Flooring covering

CableCable tieCable tube

Foam materialSpongeMelamine Foam

PaintAdhesivePigmentVarnish

FRP composite materialsSMC sheet

Braided hoseHose protection

Windowdoor framework

Small parts

ConnectorConnected equipment

pipecorrugate pipeHeating pipeCooling pipe

Other materials

Tel: (+0086) 25-8658 3475  Tel:(+0086) 25-8658 3465
Email: info@firete.com     info@fire-test.com


 Source:防火网  Addtime:5/18/2023  Hits:20438

 Previous : No related posts

 Next: NF F 16-101:1988/NF F 16-102:1992 France Standard
 
 
Home | Fire Test & Certification | Standard | News | Product | Exhibition | Flame retardant | On-line consultation | Contact us
Copyright © 2008-2024 Firete.com All Right Reserved
TEL:(+86)-25-8658 3475