首頁   美国   ASTM C991金属建筑物用挠性玻璃纤维绝缘材料标准规范
 

ASTM C991金属建筑物用挠性玻璃纤维绝缘材料标准规范

ASTM C991 Standard Specification for Flexible Fibrous Glass Insulation for Metal Buildings
ASTM C991 金属建筑物用挠性玻璃纤维绝缘材料标准规范

This specification covers the classification, composition, and physical properties of flexible fibrous glass insulation for use as interior surface of walls and roofs of metal buildings. The basic insulation blanket is designed to be postprocessed by a laminating process that applies an adhesive bonded facing to provide the interior finish and vapor retarder requirements for the building envelope The flexible insulation is furnished into Types I and II. Type I which is a glass processed from the molten state into fibrous form, bonded with a thermosetting resin, and formed into a resilient flexible blanket or batt. Type II is a Type I material supplied with a suitable facing adhered to one surface. The following physical properties of Types I and II materials shall be determined: thermal resistance, surface burning characteristics, combustion characteristics, water vapor sorption, fungi resistance, corrosiveness, odor emission, dimensional tolerances, and humid aging.
This abstract is a brief summary of the referenced standard. It is informational only and not an official part of the standard; the full text of the standard itself must be referred to for its use and application. ASTM does not give any warranty express or implied or make any representation that the contents of this abstract are accurate, complete or up to date.

1. Scope
1.1 This specification covers the classification, composition, and physical properties of flexible fibrous glass insulation for use in metal building roofs and walls.
1.2 The basic insulation blanket is designed to be post-processed by a laminating process that applies an adhesive bonded facing.
1.3 The thermal values measured in accordance with this specification for both pre-processed and post-processed insulation are for the insulation only and do not include the effects of air-film surface resistance, changes in mean temperature, or compression of insulation at the framing members of the building, through metal conductance of fasteners and other parallel heat-transfer paths due to design or installation techniques.
1.4 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.
1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory requirements prior to use.

2. Referenced Documents (purchase separately)
ASTM Standards
ASTM C167 Test Methods for Thickness and Density of Blanket or Batt Thermal Insulations
ASTM C168 Terminology Relating to Thermal Insulation
ASTM C177 Test Method for Steady-State Heat Flux Measurements and Thermal Transmission Properties by Means of the Guarded-Hot-Plate Apparatus
ASTM C390 Practice for Sampling and Acceptance of Thermal Insulation Lots
ASTM C518 Test Method for Steady-State Thermal Transmission Properties by Means of the Heat Flow Meter Apparatus
ASTM C653 Guide for Determination of the Thermal Resistance of Low-Density Blanket-Type Mineral Fiber Insulation
ASTM C665 Specification for Mineral-Fiber Blanket Thermal Insulation for Light Frame Construction and Manufactured Housing
ASTM C755 Practice for Selection of Water Vapor Retarders for Thermal Insulation
ASTM C1104/C1104M Test Method for Determining the Water Vapor Sorption of Unfaced Mineral Fiber Insulation
ASTM C1136 Specification for Flexible, Low Permeance Vapor Retarders for Thermal Insulation
ASTM C1258 Test Method for Elevated Temperature and Humidity Resistance of Vapor Retarders for Insulation
ASTM C1304 Test Method for Assessing the Odor Emission of Thermal Insulation Materials
ASTM C1338 Test Method for Determining Fungi Resistance of Insulation Materials and Facings
ASTM E84 Test Method for Surface Burning Characteristics of Building Materials
ASTM E136 Test Method for Behavior of Materials in a Vertical Tube Furnace at 750C
Other Referenced Document
CAN/ULC-S102 Standard Method of Test for Surface Burning Characteristics of Building Materials and Assemblies
Index Terms
faced insulation; metal building; thermal insulation; Building materials/applications--specifications; Faced thermal insulation--specifications; Glass thermal insulation--specifications; Metal buildings; Pre-engineered buildings--specifications;

更多防火阻燃测试认证,请咨询中国防火网
电话:400-666-7290
网址:www.firete.com
邮箱:info@firete.com

...


 來源:防火網 發布時間:12/26/2013 點擊次數:1790

 上一條: ASTM C871可浸出氯化物,氟化物,硅酸盐及钠离子用绝热材料的化学分析的标准试验方法

 下一條: ASTM D373黑色和黄色直切和偏切电绝缘棉布和带规范标准
 
 
網站首頁 | 測試服務 | 各國標準 | 新聞資訊 | 防火材料 | 會展信息 | 認證服務 | 在線咨詢 | 聯系我們
Copyright © 2009-2023 Firete.com All Right Reserved 蘇公網安備 32010502010088號
服務熱線:+86 25-86583475   備案號:苏ICP备10201999号-1 DIN5510-2 DIN5510 防火網博客