ASTM D1932 Standard Test Method for Thermal Endurance of Flexible Electrical Insulating Varnishes ASTM D1932柔性电绝缘漆耐热性的标准试验方法
A major factor affecting the long term performance of insulating materials is thermal degradation. Other factors, such as moisture and vibration, may cause failures after the material has been weakened by thermal degradation. An electrical insulating varnish is effective in protecting electrical equipment only as long as it retains its physical and electrical integrity. The thermal degradation of the varnish results in weight loss, porosity, crazing, and generally a reduction in flexibility. Degradation of the varnish can be detected by a decrease in dielectric strength, which is therefore used as the failure criterion for this test method. Electrical insulating varnishes undergo flexing in service due to vibration and thermal expansion. For this reason, this functional test includes flexing and elongation of the insulation. The electrodes used in this test method are designed to elongate the outer surface of the specimen 2 % with respect to the neutral axis of the base fiber while being tested for dielectric breakdown.
1. Scope 1.1 This test method covers the determination of the relative thermal endurance of flexible electrical insulating varnishes by determining the time necessary at elevated temperatures to decrease the dielectric breakdown of the varnish to an arbitrarily selected value when applied to a standard glass fiber fabric. 1.2 This test method does not apply to varnishes that lose a high percentage of their dielectric breakdown voltage when flexed before elevated temperature exposure as prescribed in the screening test (Section 9). Examples of such varnishes are those used for high speed armatures and laminated structures. Also, this test method is not applicable to varnishes which distort sufficiently during thermal elevated temperature exposure so that they cannot be tested using the curved electrode assembly. 1.3 Thermal endurance is expressed in terms of a temperature index. 1.4 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. Note 1—There is no equivalent IEC or ISO standard. 1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. For specific hazard statements, see Section 7.
2. Referenced Documents (purchase separately) ASTM Standards ASTM D149 Test Method for Dielectric Breakdown Voltage and Dielectric Strength of Solid Electrical Insulating Materials at Commercial Power Frequencies ASTM D374 Test Methods for Thickness of Solid Electrical Insulation ASTM D580 Specification for Greige Woven Glass Tapes and Webbings ASTM D1346 Methods of Testing Electrical Insulating Varnishes for 180C and Above ASTM D1711 Terminology Relating to Electrical Insulation ASTM D2518 Specification for Woven Glass Fabrics for Electrical Insulation ASTM D5423 Specification for Forced-Convection Laboratory Ovens for Evaluation of Electrical Insulation ASTM D6054 Practice for Conditioning Electrical Insulating Materials for Testing IEEE Publications IEEENo.101A Guide for the Statistical Analysis of Thermal Life Test Data (including Appendix A) IEC Publications IEC60216 Guide for the Determination of Thermal Endurance Properties of Electrical Insulating Materials (Part 1) Index Terms dielectric strength; glass fiber fabric; thermal endurance; varnish; Dielectric breakdown voltage; Electrical insulating varnishes; Thermal endurance--electrical insulating materials ;
更多防火阻燃测试认证,请咨询中国防火网 电话:400-666-7290 网址:www.firete.com 邮箱:info@firete.com
... |