首頁   美国   NFPA 13自动喷水灭火系统安装标准
 

NFPA 13自动喷水灭火系统安装标准

NFPA 13 STANDARD FOR THE INSTALLATION OF SPRINKLER SYSTEMS
NFPA 13 自动喷水灭火系统安装标准
 
1.1* Scope.
A.1.1 This standard provides a range of sprinkler system approaches, design development alternatives, and component options that are all acceptable. Building owners and their designated representatives are advised to carefully evaluate proposed selections for appropriateness and preference.
1.1.1 This standard shall provide the minimum requirements for the design and installation of automatic fire sprinkler systems and exposure protection sprinkler systems covered within this standard.
1.1.2 This standard is written with the assumption that the sprinkler system shall be designed to protect against a single fire originating within the building.
 
Get up-to-code with new research-based 2010 NFPA 13.
Put powerful sprinkler strategies into your toolkit with NFPA 13 Standard for the Installation of Sprinkler Systems -- the new best practices for system design, installation, water supplies, and equipment. Industry experts and researchers worked together to solidify new knowledge about sprinkler performance under fire conditions. The 2010 edition of NFPA 13 is current with the latest sprinkler technology, delivering scientifically-based solutions that reduce risks and fire loss.
Fire testing and studies performed by the Fire Protection Research Foundation form the basis for added criteria.
·   Chapter 20 presents requirements for the protection of three new special storage arrangements
·   Carton records storage with catwalk access
·   Compact shelving of commodities including paper files, magazines, books and similar documents in folders -- with no more than 5% plastics and up to 8 ft. high
·   High-bay records storage
The 2010 NFPA 13 keeps your work in line with SEI/ASCE 7.
NFPA 13 adopts the SEI/ASCE 7 approach for load calculations, and new Annex E describes the process. To recognize the wide range of pipe materials used in today's systems, NFPA 13 introduces new zone-of-influence tables for Schedule 5 steel pipe, CPVC, and Type M copper tube.
Other major technical revisions and usability changes
·   New method to calculate rack shelf area takes the placement of loads into consideration.
·   Information about large drop sprinklers and specific application control mode sprinklers is combined as Control Mode Specific Application (CMSA).
·   Added criteria for the use of smoke vents recognize their limited use and effect on sprinkler operation.
Put the latest research and fire experience to work.
Keep pace with dynamic advancements and ensure systems are designed and installed correctly with the 2010 edition of NFPA 13. (Softbound, 414 pp., 2010)

更多防火阻燃测试认证,请咨询中国防火网
电话:400-666-7290
网址:www.firete.com
邮箱:info@firete.com

...


 來源:防火網 發布時間:12/6/2013 點擊次數:1783

 上一條: NFPA 13R不超过4层住宅自动喷水灭火系统安装标准

 下一條: NFPA 14立管和水带系统安装标准
 
 
網站首頁 | 測試服務 | 各國標準 | 新聞資訊 | 防火材料 | 會展信息 | 認證服務 | 在線咨詢 | 聯系我們
Copyright © 2009-2023 Firete.com All Right Reserved 蘇公網安備 32010502010088號
服務熱線:+86 25-86583475   備案號:苏ICP备10201999号-1 DIN5510-2 DIN5510 防火網博客