主要阻燃防火認證標準 |
|
| 火車船舶汽車建材 |
|
|
 |
| |
|
 |
| |
首頁 常用标准 南京睿督分享:建築用排煙風管EN12101-7歐盟CE認證 |
| |
南京睿督分享:建築用排煙風管EN12101-7歐盟CE認證
|
EN12101-7排煙風管CE認證
關聯測試標準:需結合耐火試驗標準使用,主要包括 EN 1366-8(排煙管道耐火試驗)、EN 1366-9(單室排煙管)及 EN 1366-1(一般管道)。
防火分類依據:試驗資料需參照 EN 13501-4 進行建築產品和構件的防火分類 。
市場准入:屬於歐盟《建築產品法規》(CPR 305/3011/EU)管轄範圍,出口歐盟需進行CE認證並簽署性能聲明(DoP)。
EN 12101-7 Smoke and heat control systems - Part 7: Smoke duct sections
EN 12101-7是專門針對“煙霧和熱量控制系統第7部分:排煙風管”的協調標準。
EN 12101-7 主要測試項目
環境洩漏測試 (Ambient leakage tests)
在非火災的常溫環境下,測試排煙管道系統的氣密性,確保其在日常狀態下的密封性能。
耐火測試 (Fire resistance tests)
模擬火災高溫條件,檢驗管道在火場中的完整性和隔熱性。此部分又分為:
完整性和隔熱性測試:檢驗排煙管道在火災中是否保持結構完整(不破裂)以及其隔熱性能。
洩漏率測試:檢驗排煙管道在火災高溫下的洩漏量是否符合要求。
EN12101-7 INTRODUCTION
EN 12101-7 is a standard applied in Europe for the design, installation, and maintenance of smoke control and ventilation systems in buildings. This standard was developed to ensure the rapid evacuation of smoke and to maintain building safety during a fire. Properly managed smoke and heat during a fire aim to allow safe evacuation of occupants and to prevent the spread of the fire.
EN 12101-7 sets out the necessary requirements and performance criteria to ensure the safe and efficient operation of smoke control systems. These systems are commonly referred to as “Heat and Smoke Ventilation Systems” (HVS), which are used to remove smoke and heat from buildings.
Objectives of EN 12101-7
The EN 12101-7 standard aims to achieve the following key goals during fire incidents:
Containment and removal of smoke from the building.
Safe evacuation of occupants.
Control and suppression of fire spread.
Preservation of the structural integrity of buildings to enhance fire safety.
To achieve these objectives, the components used in the design of heat and smoke ventilation systems must be correctly specified, positioned, and tested.
EN 12101-7 covers various components of smoke control systems, including:
Smoke Ventilation Systems: Systems that safely evacuate smoke from the building. These typically consist of ventilation ducts, fans, and exhaust outlets.
Mechanical Ventilation Systems: Used to control airflow in the building during a fire, allowing occupants to evacuate through smoke-free areas.
Fans and Motors: Electrically operated devices that play a critical role in expelling smoke quickly from the building.
Operable Windows and Air Outlets: Windows and vents that can be opened to allow smoke to escape are also part of the system.
Performance Requirements
EN 12101-7 provides specific performance criteria to assess the effectiveness of the systems, including:
Rapid Smoke Evacuation: Smoke must be removed from the building as quickly as possible.
High Heat Resistance: System components must be resistant to the high temperatures associated with fires.
Reliability: The smoke ventilation system must function reliably during a fire.
Maintenance and Testing Requirements: Systems must be regularly maintained and tested.
自然排煙天窗EN 12101-2標準名稱
EN 12101-2:2003 Smoke and heat control systems Part 2: Specification for natural smoke and heat control exhaust ventilators
EN 12101-2:2003 煙氣和熱控制系統第2部分:自然煙氣和熱控排氣通風設備規範
電動排煙風機EN 12101-3標準名稱
EN 12101-3:2015 Smoke and heat control systems Part 3: Specification for powered smoke and heat control ventilators (Fans)
EN 12101-3:2015 煙氣和熱控制系統第3部分:電動煙氣和熱控通風設備(風機)規範
南京睿督為歐盟公告號Notified Body實驗室授權合作單位,可以直接受理EN12101排煙通風設備CE認證。
南京睿督全國免費諮詢電話:+86 258658 3465 +86 25-8658 3475