| 1. NF P92-501 Fire test to Building materials M classification - Standard NF P92-501: Building materials-Reaction to fire tests, radiation test used for rigid material or flexible materials thickness more than 5mm.
 
 2. NF P92-501 Fire test to Building materials M classification - Test Method
 Specimens of the product are mounted in an enclosed chamber at an angle of 45° to the horizontal and exposed to thermal radiation (30kW/m2) on their lowest surface, the test duration 20 minutes.
 
 The materials is classified M1 to M4 according to the q index (NF P92-507)
 M1 - Non flammable           q < 2.5
 M2 - Low flammability        q < 15
 M3 - Moderately flammable    q < 50
 M4–flammable                q ≥50
 
 
 
	If specific, unusual, specimen behaviour is observed additional supplementary tests (NF P 92-504 or NF P 92-505) may be required.  
 
	  3. NF P92-501 Fire test to Building materials M classification - Similar Standard
 NF P92-501: Building materials- Reaction to fire tests, radiation test used for rigid material or flexible materials thickness more than 5mm.
 NF P92-503: Electrical burner test used for flexible materials thickness no more than 5mm
 NF P92-504: speed of spread of flame test used for the materials which are not intended to be glued on a rigid substrate
 NF P92-505: Dripping test with electrical radiator, used for melting materials
 NF P92-506: Fire safety, Building materials, Reaction for fire tests, Radiant panel test for flooring
 NF P92-507: Fire safety, Building materials, Construction and furnishing materials –Classification according to reaction to fire.
 