首页   美国   ASTM C1153用红外线影象为屋面防潮定位
 

ASTM C1153用红外线影象为屋面防潮定位

ASTM C1153 Standard Practice for Location of Wet Insulation in Roofing Systems Using Infrared Imaging
ASTM C1153用红外线影象为屋面防潮定位

This practice is used to outline the minimum necessary elements and conditions to obtain an accurate determination of the location of wet insulation in roofing systems using infrared imaging.
This practice is not meant to be an instructional document or to provide all the knowledge and background necessary to provide an accurate analysis. For further information, see ANSI-ASHRAE Standard 101 and ISO/DP 6781.3E.
This practice does not provide methods to determine the cause of moisture or its point of entry. It does not address the suitability of any particular system to function capably as waterproofing.

1. Scope
1.1 This practice applies to techniques that employ infrared imaging at night to determine the location of wet insulation in roofing systems that have insulation above the deck in contact with the waterproofing. This practice includes ground-based and aerial inspections. (Warning—Extreme caution shall be taken when accessing or walking on roof surfaces and when operating aircraft at low altitudes, especially at night.) (Warning—It is a good safety practice for at least two people to be present on the roof surface at all times when ground-based inspections are being conducted.)
1.2 This practice addresses criteria for infrared equipment such as minimum resolvable temperature difference, spectral range, instantaneous field of view, and field of view.
1.3 This practice addresses meteorological conditions under which infrared inspections shall be performed.
1.4 This practice addresses the effect of roof construction, material differences, and roof conditions on infrared inspections.
1.5 This practice addresses operating procedures, operator qualifications, and operating practices.
1.6 This practice also addresses verification of infrared data using invasive test methods.
1.7 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.
1.8 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. Specific precautionary statements are given in 1.1.

2. Referenced Documents (purchase separately)
ASTM Standards
ASTM C168 Terminology Relating to Thermal Insulation
ASTM D1079 Terminology Relating to Roofing and Waterproofing
ASTM E1149 Definitions of Terms Relating to NDT by Infrared Thermography
ASTM E1213 Test Method for Minimum Resolvable Temperature Difference for Thermal Imaging Systems
ANSI-ASHRAE Standard
ANSI-ASHRAEStandard1 of Infrared Sensing Devices to the Assessment of Building Heat Loss Characteristics
ISO Standard
ISO/DP6781.3E— Insulation--Qualitative Detection of Thermal Irregularities in Building Envelopes--Infrared Method
Index Terms
infrared; in-situ; moisture; roofing systems; thermal insulation; Infrared (IR) analysis; In-situ inspection/analysis; Locations; Roof insulation; Thermal insulating materials; Wet insulation;

更多防火阻燃测试认证,请咨询中国防火网
电话:400-666-7290
网址:www.firete.com
邮箱:info@firete.com

...


 来源:防火网  发布时间:12/9/2013  点击次数:2373

 上一条: ASTM C1149自支撑喷涂纤维素质绝热材料的标准规范

 下一条: ASTM C1166致密及多孔弹性衬垫和附件的火焰蔓延标准试验方法
 
 
网站首页 | 测试服务 | 各国标准 | 新闻资讯 | 防火材料 | 会展信息 | 认证服务 | 在线咨询 | 联系我们
Copyright © 2009-2024 Firete.com All Right Reserved 苏公网安备 32010502010088号
服务热线:025-86583475   备案号:苏ICP备10201999号-1 DIN5510-2 DIN5510 防火网博客