防火网
本站  
设为首页 加入收藏 网站地图   中文版 繁体 English
 
测试服务: 机车材料防火测试 | 建筑产品防火测试 | 船舶防火测试 | 飞机防火测试 | 耐火测试 | 喷射火测试 | 其他测试
   
用户名:
密码:
验证码:
   
 
主要阻燃防火认证标准
火车船舶汽车建材
 
相关测试方法 更多>>
EN ISO 9239-1:2010地
EN ISO 1182:2010
NF P 92-501
NF P 92-507
法标F级测试
法标I级测试
法国M级测试
EN ISO 1182
EN ISO 9239-1
EN 13501-1
 
首页   美国   ASTM E413隔音等级的分类
 

ASTM E413隔音等级的分类

ASTM E413 Classification for Rating Sound Insulation
ASTM E413 隔音等级的分类

These single-number ratings correlate in a general way with subjective impressions of sound transmission for speech, radio, television, and similar sources of noise in offices and buildings. This classification method is not appropriate for sound sources with spectra significantly different from those sources listed above. Such sources include machinery, industrial processes, bowling allies, power transformers, musical instruments, many music systems, and transportation noises such as motor vehicles, aircraft and trains. For these sources, accurate assessment of sound transmission requires a detailed analysis in frequency bands. A single-number sound transmission rating for building faade elements is given in Classification E1332.
The single-number ratings obtained can be used to compare the potential sound insulation of partitions or floors tested in laboratory conditions (STC) or the actual sound isolation between different suites in buildings (NNIC, NIC). The rating for a partition built and tested in a building may be lower than that obtained for a partition tested in a laboratory because of flanking transmission or construction errors.
Note 1—A similar rating procedure, described in ISO 717, provides single figure sound insulation ratings with a frequency range that extends from 100 to 3150 Hz with no maximum deficiency specified at individual frequencies. For most partitions, the two ratings differ by only one or two points.

1. Scope
1.1 This classification covers methods of calculating single-number acoustical ratings for laboratory and field measurements of sound attenuation obtained in one-third octave bands.
1.2 The name given to the single-number rating is assigned by the test method that invokes this classification.
1.3 Test methods that invoke this classification include:
1.3.1 Test Method E90—The single-number rating is called sound transmission class (STC).
1.3.2 Test Method E336—Single-number ratings are field sound transmission class (FSTC), noise isolation class (NIC), and normalized noise isolation class (NNIC).
1.3.3 Test Method E596—The single-number rating is called noise isolation class (NIC).
1.3.4 Test Method E1414—The single-number rating is called ceiling attenuation class (CAC).
1.4 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.

2. Referenced Documents (purchase separately)
ASTM Standards
ASTMC634 Terminology Relating to Building and Environmental Acoustics
ASTME90 Test Method for Laboratory Measurement of Airborne Sound Transmission Loss of Building Partitions and Elements
ASTME336 Test Method for Measurement of Airborne Sound Attenuation between Rooms in Buildings
ASTME596 Test Method for Laboratory Measurement of Noise Reduction of Sound-Isolating Enclosures
ASTME1332 Classification for Rating Outdoor-Indoor Sound Attenuation
ASTME1414 Test Method for Airborne Sound Attenuation Between Rooms Sharing a Common Ceiling Plenum
ISO Standard
ISO717 Rating of Sound Insulation for Dwellings
Index Terms
architectural acoustics; building design; ceiling attenuation class (CAC); field sound transmission class (FSTC); noise isolation class (NIC); normalized noise isolation class (NNIC); partitions (buildings); sound insulation rating; sound transmission class (STC); Acoustical materials/applications; Architectural acoustics; Chemical-resistant mortars; Classification (standards)--acoustic materials; Field sound transmission class (FSTC); Field testing--sound transmission; Noise isolation class (NIC); Normalized noise isolation class (NNIC); One-third octave band sound pressure levels; Partitions; Sound absorbing/insulating materials/applications; Sound transmission--building materials/applications; Sound transmission class (STC);

更多防火阻燃测试认证,请咨询中国防火网
电话:400-666-7290
网址:www.firete.com
邮箱:info@firete.com

...


 


 来源:防火网  发布时间:11/19/2013  点击次数:2776

 上一条: ASTM E357用过氧化钠弹燃烧法测定有机化合物中磷试验方法

 下一条: ASTM E574用玻璃纤维或硅纤维绝缘的双重基础金属热电偶丝的标准规范
 
 
网站首页 | 测试服务 | 各国标准 | 新闻资讯 | 防火材料 | 会展信息 | 认证服务 | 在线咨询 | 联系我们
Copyright © 2009-2024 Firete.com All Right Reserved 苏公网安备 32010502010088号
服务热线:025-86583475   备案号:苏ICP备10201999号-1 DIN5510-2 DIN5510 防火网博客