首页   美国   ASTM D6096 90°C 操作的电线和电缆用聚氯乙烯绝缘的标准规范
 

ASTM D6096 90°C 操作的电线和电缆用聚氯乙烯绝缘的标准规范

ASTM D6096 Standard Specification for Poly(Vinyl Chloride) Insulation for Wire and Cable, 90°C Operation
ASTM D6096 90操作的电线和电缆用聚氯乙烯绝缘的标准规范

This specification covers poly(vinyl chloride) thermoplastic insulation for conducting wires and cables operating continuously at a specified conductor temperature, within the specified voltage range, and under wet or dry conditions. The insulation has potential low-temperature installation limitations. The prescribed tests cannot be performed unless the insulation is formed around a conductor, but these are done solely to determine the insulation properties and not to test the conductor or completed cable. Each test sample should be subjected to an ac and dc voltage withstand tests and insulation resistance test and should comply with the required values for unaged and aged requirements of tensile strength and elongation at rupture, heat shock, heat distortion, vertical flame test results, oil resistance, and cold bend test results. All joints and repairs in the insulation should be done in such a way as the affected parts meet the same electrical requirements as the rest of the insulation.
This abstract is a brief summary of the referenced standard. It is informational only and not an official part of the standard; the full text of the standard itself must be referred to for its use and application. ASTM does not give any warranty express or implied or make any representation that the contents of this abstract are accurate, complete or up to date.

1. Scope
1.1 This specification covers a thermoplastic insulation of poly (vinyl chloride) or the copolymer of vinyl chloride and vinyl acetate. This insulation is recommended for use at conductor temperatures not in excess of 90°C.
1.2 Depending on the thickness of the insulation, the maximum voltage used, and whether the location is wet or dry, this insulation is acceptable for use in 300 V (dry) and 600 V (wet or dry) power and control circuits.
1.3 This insulation has potential low-temperature installation limitations. Consult the manufacturer for specific recommendations for installation.
1.4 In many instances, the insulation material cannot be tested unless it has been formed around a conductor or cable. Therefore, tests are done on insulated wire or cable in this specification solely to determine the relevant property of the insulation material and not to test the conductor or completed cable.
1.5 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.
1.5.1 In some cases (including the title), temperatures are described in degrees Celsius only.

2. Referenced Documents (purchase separately)
ASTM Standards
ASTM D1711 Terminology Relating to Electrical Insulation
ASTM D2633 Test Methods for Thermoplastic Insulations and Jackets for Wire and Cable
Index Terms
accelerated water absorption; ac voltage test; dc voltage test; insulation resistance; poly(vinyl chloride) insulation; 90 C poly(vinyl chloride) insulation; thickness;

更多防火阻燃测试认证,请咨询中国防火网
电话:400-666-7290
网址:www.firete.com
邮箱:info@firete.com

...


 来源:防火网  发布时间:11/14/2013  点击次数:2030

 上一条: ASTM D6095挤制交联和热塑半导性导体和绝缘防护材料体电阻率的经度测量标准试验方法

 下一条: ASTM D6097固体介电绝缘材料抗水树生长性能的试验方法
 
 
网站首页 | 测试服务 | 各国标准 | 新闻资讯 | 防火材料 | 会展信息 | 认证服务 | 在线咨询 | 联系我们
Copyright © 2009-2024 Firete.com All Right Reserved 苏公网安备 32010502010088号
服务热线:025-86583475   备案号:苏ICP备10201999号-1 DIN5510-2 DIN5510 防火网博客