主要阻燃防火认证标准 |
|
| 火车船舶汽车建材 |
|
|
 |
| |
|
 |
| |
首页 常用标准 南京睿督分享:建筑用排烟风管EN12101-7欧盟CE认证 |
| |
南京睿督分享:建筑用排烟风管EN12101-7欧盟CE认证
|
EN12101-7排烟风管CE认证
关联测试标准:需结合耐火试验标准使用,主要包括 EN 1366-8(排烟管道耐火试验)、EN 1366-9(单室排烟管)及 EN 1366-1(一般管道)。
防火分类依据:试验数据需参照 EN 13501-4 进行建筑产品和构件的防火分类 。
市场准入:属于欧盟《建筑产品法规》(CPR 305/3011/EU)管辖范围,出口欧盟需进行CE认证并签署性能声明(DoP)。
EN 12101-7 Smoke and heat control systems - Part 7: Smoke duct sections
EN 12101-7是专门针对“烟雾和热量控制系统第7部分:排烟风管”的协调标准。
EN 12101-7 主要测试项目
环境泄漏测试 (Ambient leakage tests)
在非火灾的常温环境下,测试排烟管道系统的气密性,确保其在日常状态下的密封性能。
耐火测试 (Fire resistance tests)
模拟火灾高温条件,检验管道在火场中的完整性和隔热性。此部分又分为:
完整性和隔热性测试:检验排烟管道在火灾中是否保持结构完整(不破裂)以及其隔热性能。
泄漏率测试:检验排烟管道在火灾高温下的泄漏量是否符合要求。
EN12101-7 INTRODUCTION
EN 12101-7 is a standard applied in Europe for the design, installation, and maintenance of smoke control and ventilation systems in buildings. This standard was developed to ensure the rapid evacuation of smoke and to maintain building safety during a fire. Properly managed smoke and heat during a fire aim to allow safe evacuation of occupants and to prevent the spread of the fire.
EN 12101-7 sets out the necessary requirements and performance criteria to ensure the safe and efficient operation of smoke control systems. These systems are commonly referred to as “Heat and Smoke Ventilation Systems” (HVS), which are used to remove smoke and heat from buildings.
Objectives of EN 12101-7
The EN 12101-7 standard aims to achieve the following key goals during fire incidents:
Containment and removal of smoke from the building.
Safe evacuation of occupants.
Control and suppression of fire spread.
Preservation of the structural integrity of buildings to enhance fire safety.
To achieve these objectives, the components used in the design of heat and smoke ventilation systems must be correctly specified, positioned, and tested.
EN 12101-7 covers various components of smoke control systems, including:
Smoke Ventilation Systems: Systems that safely evacuate smoke from the building. These typically consist of ventilation ducts, fans, and exhaust outlets.
Mechanical Ventilation Systems: Used to control airflow in the building during a fire, allowing occupants to evacuate through smoke-free areas.
Fans and Motors: Electrically operated devices that play a critical role in expelling smoke quickly from the building.
Operable Windows and Air Outlets: Windows and vents that can be opened to allow smoke to escape are also part of the system.
Performance Requirements
EN 12101-7 provides specific performance criteria to assess the effectiveness of the systems, including:
Rapid Smoke Evacuation: Smoke must be removed from the building as quickly as possible.
High Heat Resistance: System components must be resistant to the high temperatures associated with fires.
Reliability: The smoke ventilation system must function reliably during a fire.
Maintenance and Testing Requirements: Systems must be regularly maintained and tested.
自然排烟天窗EN 12101-2标准名称
EN 12101-2:2003 Smoke and heat control systems Part 2: Specification for natural smoke and heat control exhaust ventilators
EN 12101-2:2003 烟气和热控制系统第2部分:自然烟气和热控排气通风设备规范
电动排烟风机EN 12101-3标准名称
EN 12101-3:2015 Smoke and heat control systems Part 3: Specification for powered smoke and heat control ventilators (Fans)
EN 12101-3:2015 烟气和热控制系统第3部分:电动烟气和热控通风设备(风机)规范
南京睿督为欧盟公告号Notified Body实验室授权合作单位,可以直接受理EN12101排烟通风设备CE认证。
南京睿督全国免费咨询电话:400-603-6575 025-8658 3475
网址:www.hksmartps.com www.cprce.com