防火阻燃测试--中国防火网 400-603-6575

中国防火网专注于英国防火测试BS6853,法国防火测试NFF16-101,德国防火测试DIN5510-2,美国防火测试NFPA130,欧标EN45545等防火阻燃测试

« DIN5510/DIN5510-2德国防火阻燃测试,聚氨酯胶黏剂机车材料—南京睿督服务公司DIN5510/DIN5510-2德国防火阻燃测试,硅橡胶机车材料—南京睿督服务公司 »

电线电缆防火阻燃测试标准 Cable test standard

Fire resisting、Non propagation of fire、Flame retardant test、Smoke density、Toxicity、
Corrosivity、HCI emission、

BS 4066-1(EN 50265): Method of test on a single vertical insulated wire or cable.

BS 4066-3 EN 50266): Method for classification of flame propagation

characteristics of bunched cables.

BS 6387: Specification for performance requirements for cables requirement to maintain circuit integrity

under fire conditions.

BS 6245-1 (EN 50267-2-1): Method of determination of amount of halogen acid gas evolved during combustion

of polymeric materials taken from cables.

BS 6425-2 (EN 50267-2-2): Determination of degree of acidity (corrosivity) of gases by measuring PH and

conductivity.

BS 6724, Appendix F: Measurement of smoke density using the 3m test cube (Absorbance).

BS 7622 (EN 50268): Measurement of smoke density of electric cables burning under defined conditions

(LT).

CEI 20-17: Fire retardant rubber insulated cables with low emission of smokes and toxic and corrosive

gases for train, trams and alike.

CEI 20-22-2 (EN 50266): Tests on bunched wires or cables

CEI 20-35-1(EN 50265): Test on a single vertical insulated wire or cable.

CEI 20-36: Fire-resisting characteristics of electric cables.

CEI 20-37-2-1(EN 50267-2-1): Method for determination of amount of halogen acid gas evolved during

combustion of polymeric materials taken from cables.

CEI 20-37-2-2(EN 50267-2-12): Determination of degree of acidity (corrosivity) of gases by measuring PH

and conductivity.

CEI 20-37-3 (EN 50268-1): Measurement of smoke density of electric cables burning under defined

conditions (LT).

CEI 20-38: Fire retardant rubber insulated cables with low emission of smoke and toxic and corrosive

gases.

DEF STD 61-12-18: Equipment wires limited fire hazard.
DIN 4102-12: Circuit integrity maintenance of electric cable systems-Requirements and testing.

EN 50200:2000-02—Methods of test for resistance to fire of unprotected smell cables for use in emergency

circuit.

IEC 60331: Fire-resisting characteristics of electric cables.

IEC 60332-1: Test on a single vertical insulated wire or cable

IEC 60332-2: Test on a single small vertical insulated copper wire or cable

IEC 60332-3: Test on bunched wires or cables.

IEC 60754-1: Method for determination of amount of halogen acid gas evolved during combustion of

polymeric materials taken from cables.

IEC 60754-2: Measurement of smoke density of electric cables burning under defined conditions (LT).

IEC 61034-2: Measurement of smoke density of electric cables burning under defined condition (LT).

IEEE 383, Section 2.5.1: Flame test on grouped cables in vertical tray.

NES 713: Determination of the toxicity index of the products of combustion from small specimens of

material.

NF X 70-100: Fire behaviour tests-Analysis of pyrolysis and combustion gased-Pipe still method.

NF C 32-070: Insulated conductors and cables for installation

classification tests on conductors and cables with regard to fire behaviour.

Singapore Std 299-1: Performance requirement for cables required to maintain circuit integrity under fire

conditions.

UIC 895: Technical specification for the supply of insulated electric cables for railway vehicles.

UITP-APTA: Electric wires and cables used in underground transit systems.

UTE C 20-454: Test method, fire behaviour, determination of gases analysis.

VDE 0472-814: Testing of cables and flexible cords fire resisting characteristics of electric cables.


中国防火网专业提供BS6853测试、NFF16-101测试、DIN5510-2测试、NFPA130测试

全国免费咨询电话: 400-666-7290

 

  • 相关文章:

发表评论:

◎欢迎参与讨论,请在这里发表您的看法、交流您的观点。

日历

最新评论及回复

最近发表

Powered By DIN5510-2 DIN5510

中国防火网 版权所有