ASTM D5537电缆或光缆防火测试测试标准 ASTM D5537 Standard Test Method for Heat Release, Flame Spread, Smoke Obscuration, and Mass Loss Testing of Insulating Materials Contained in Electrical or Optical Fiber Cables When Burning in a Vertical Cable Tray Configuration ASTM D5537电缆或光缆绝缘材料在立式电缆槽装置中燃烧时热发散,火焰传播,烟的昏暗度和质量损失测试的标准试验方法
1. ASTM D5537电线电缆测试适用范围Scope 1.1 This is a fire-test-response standard. 1.2 This test method provides a means to measure the heat released and smoke obscuration by burning the electrical insulating materials contained in electrical or optical fiber cables when the cable specimens, excluding accessories, are subjected to a specified flaming ignition source and burn freely under well ventilated conditions. Flame propagation cable damage, by char length, and mass loss are also measured. 1.3 This test method provides two different protocols for exposing the materials, when made into cable specimens, to an ignition source (approximately 20 kW), for a 20 min test duration. Use it to determine the heat release, smoke release, flame propagation and mass loss characteristics of the materials contained in single and multiconductor electrical or optical fiber cables. 1.4 This test method does not provide information on the fire performance of materials insulating electrical or optical fiber cables in fire conditions other than the ones specifically used in this test method nor does it measure the contribution of the materials in those cables to a developing fire condition. 1.5 Data describing the burning behavior from ignition to the end of the test are obtained. 1.6 This test equipment is suitable for measuring the concentrations of certain toxic gas species in the combustion gases (see Appendix X4). 1.7 The values stated in SI units are to be regarded as standard (see ). The values given in parentheses are mathematical conversions to inch-pound units that are provided for information only and are not considered standard. 1.8 This standard measures and describes the response of materials, products, or assemblies to heat and flame under controlled conditions, but does not by itself incorporate all factors required for fire hazard or fire risk assessment of the materials, products or assemblies under actual fire conditions.. 1.9 Fire testing is inherently hazardous. Adequate safeguards for personnel and property shall be employed in conducting these tests. 1.10 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
2.ASTM D5537电线电缆参考标准 ASTM E1354 Test Method for Heat and Visible Smoke Release Rates for Materials and Products Using an Oxygen Consumption Calorimeter UL 1685 Vertical-Tray Fire-Propagation and Smoke-Release Test for Electrical and Optical‐Fiber Cables IEC 60332-3 Tests on electric cables under fire conditions-Part 3: Test for vertical flame spread of vertically-mounted bunched wires or cables
我们同时还提供英国电缆BS6853、德国电缆DIN5510、欧盟电缆EN45545、法国电缆NFF16-101/NFF16-102等 英国电缆BS6853测试 http://www.fire-test.com/teststandard/bs6853cabletesting/3244.html 德国电缆DIN5510-2测试 http://www.fire-test.com/teststandard/din5510-2cabletesting/3245.html 法国电缆NFF16-101测试 http://www.fire-test.com/teststandard/nff16-101cabletesting/3246.html 美国电缆NFPA130测试 http://www.fire-test.com/teststandard/nfpa130cabletesting/3247.html 电缆EN 45545-2-2013欧盟最新标准 http://www.fire-test.com/teststandard/en45545-2cabletesting/3248.html
更多关于ASTM D5537电线电缆防火性能,火焰传播,烟的昏暗度和质量损失测试,请咨询南京睿督公司 南京睿督公司免费咨询电话:025-8658 3475 400-603-6575 网址:www.fire-test.com 邮箱:info@fire-test.com
… |