Home station  
Set as homepage Add to favorites    中文版 繁体 English
 
Testing to: Rolling Fire testing | Building Fire testing | Marine material | Aircraft material | Fire Resistance | Jet Fire | Other
   
User name:
Password:
Code:
   
Fire standard
RailwayMarineBusBuilding
Test method More>>
BS 476-6:1989+A1:2009 fire...
BS 476-7:1997 Classificati...
BS 476-20:1987 fire resist...
BS ISO 4589-2:2006-06
NF P 92-501: M classificat...
NF P 92-503: M classificat...
NF P 92-504: Speed of spre...
ASTM E 662: Smoke density ...
ASTM E 648 Flooring test
ASTM E 162: surface flamma...
 
Home   Popular Standard   NF F 16-101/NF X 70-100: Toxicity Testing
 

NF F 16-101/NF X 70-100: Toxicity Testing

NF F 16-101/NF X 70-100: Toxicity Testing

 

1. Standard-- NF F 16-101/NF X 70-100

NF X 70-100: Fire behaviour tests –Analysis of pyrolysis and combustion gases-Pipe still method.

The test is conducted within a tube furnace where the temperature is set at either 400°C, 600°C or 800°C (commonly600°C is used for most materials or 800°C in the case of some electrical products). 40 minutes throughout the test. By (CO, CO2, HCI, HBr, HCN, HF, SO2) analysis of these gases toxicity index.

 

2. NF F 16-101/NF X 70-100 for assessing F classification (smoke density and toxicity)

NF X 10-702 for assessing F classification (smoke density and toxicity)

NF F 16-101:1988 referenced in this standard (NF X 70-100) and the NF X 10-702 for the F-level smoke toxicity testing

According to NF X 70-100 and NF X 10-702 results of two tests to assess the toxicity of F-class level of F0-F5 smoke six levels (F0, F1, F2, F3, F4, F5)

 

Class

Value of S.I.

F0

5

F1

20

F2

40

F3

80

F4

120

F5

120

 

3NF F 16-101/NF X 70-100 test methods

NF X 10-702: Fire test methods-Smoke emission-Test of measurement of specific optical density of smoke by the combustion or the pyrolysis of solid materials.

NF X 70-100: Fire behaviour tests –Analysis of pyrolysis and combustion gases-Pipe still method.

NF F 16-101: Railway rolling stock fire behaviour choice of materials

NF F 16-102 : Railway rolling stock fire behaviour choice of materials-Electrical Equipment

 

Tel: (+86)025-8658 3475


 Source:防火网  Addtime:10/22/2010  Hits:5790

 Previous : NF F 16-101/NF X 10-702: Smoke density

 Next: BS 6853/BS 6853 Annex B: toxicity test
 
 
Home | Fire Test & Certification | Standard | News | Product | Exhibition | Flame retardant | On-line consultation | Contact us
Copyright © 2008-2024 Firete.com All Right Reserved
TEL:(+86)-25-8658 3475