Home station  
Set as homepage Add to favorites    中文版 繁体 English
 
Testing to: Rolling Fire testing | Building Fire testing | Marine material | Aircraft material | Fire Resistance | Jet Fire | Other
   
User name:
Password:
Code:
   
Fire standard
RailwayMarineBusBuilding
Test method More>>
BS 476-6:1989+A1:2009 fire...
BS 476-7:1997 Classificati...
BS 476-20:1987 fire resist...
BS ISO 4589-2:2006-06
NF P 92-501: M classificat...
NF P 92-503: M classificat...
NF P 92-504: Speed of spre...
ASTM E 662: Smoke density ...
ASTM E 648 Flooring test
ASTM E 162: surface flamma...
 
Home   Popular Standard   NF F 16-101/IEC 60695-2-11:2000 Glow-wire flammability test
 

NF F 16-101/IEC 60695-2-11:2000 Glow-wire flammability test

NF F 16-101/IEC 60695-2-11:2000 Glow-wire flammability test

 

1Standard--- NF F 16-101/IEC 60695-2-11:2000

IEC 60695-2-11: Glawing/hot wire based test methods-Glow-wire flammability test method for end-products.

The standards replace NF C 20-455

 

2Scope-- NF F 16-101/IEC 60695-2-11:2000

This standard generally used for small-size material (final product) of the combustion properties of the test.


NF F 16-101:1988 referenced in this standard (IEC 60695-2-11) and EN ISO 4589-2 for I-level oxygen index test.

According to IEC 60695-2-11 and EN ISO 4589-2 two test results, I assess the level of oxygen that level I0-I4 five levels (I0, I1, I2, I3, I4).



 

Class

Result of Tests

O.I.

Glow wire

I0

≥70

No ignition at 960

I1

≥45

No ignition at 960

I2

≥32

No ignition at 850

I3

≥28

Ignition does not persist at 850 after glow wire is withdrawn

I4

≥20

NC1

20

NC1: Non-classified

 

Glow wire apply the test temperature is 850 and 960

 

3Other standard--- NF F 16-101/IEC 60695-2-11:2000

IEC 60695-2-Fire hazard testing-Part 2: Glawing/hot wire based test methods, consists of the following parts:

IEC 60695-2-10: Glawing/hot wire based test methods-Glow-wire apparatus and common test procedure.

IEC 60695-2-11: Glawing/hot wire based test methods-Glow-wire flammability test method for end-products.

IEC 60695-2-12: Glawing/hot wire based test methods-Glow-wire flammability test method for materials.

IEC 60695-2-13: Glawing/hot wire based test methods-Glow-wire ignitability test method for materials.

 

(+86) 025-8658 3475


 Source:防火网  Addtime:10/22/2010  Hits:4566

 Previous : NF F 16-101/ EN ISO 4589-2 Ambient-temperature oxygen index test

 Next: NF F 16-101/NF X 10-702: Smoke density
 
 
Home | Fire Test & Certification | Standard | News | Product | Exhibition | Flame retardant | On-line consultation | Contact us
Copyright © 2008-2024 Firete.com All Right Reserved
TEL:(+86)-25-8658 3475