NF F 16-101/NF P 92-503: M classification combustion test

 

1. Standard-- NF F 16-101/NF P 92-503

NF P 92-503: Electrical burner test used for flexible materials thickness no more than 5mm

2. Test method—NF F 16-101/NF P 92-503

A specimen in placed in a specimen holder at 30° above a radiator which gives out heat(30kW/m²). A small butane flame is applied directly to the fabric surface.  The following aspects are recorded:  

- duration of the flame

- production of burning droplets

- length/width of the damaged specimen

If specific, unusual, specimen behaviour is observed additional supplementary tests NF P 92-504 & NF P 92-505) may be required.

 

 

3. M Classification : M0-M4(M0M1M2M3M4)

 

Method

Classes

NF P 92 - 505

-

No ignition of the wool

No ignition of the wool

Ignition of the wool

Ignition of the wool

NF P 92 - 503

No droplets

Not-burning droplets

Burning droplets

Not-burning droplets

Burning droplets

Ignition time =< 5s

M1

M1

M2

M4

M4

Ignition time > 5s; damaged length < 350mm

M2

M2

M3

M4

M4

Ignition time > 5s; damaged length between 450mm and 600mm; damaged width < 90mm

M3

M3

M4

M4

M4

NF P 92 - 504

-

-

M4

M4

M4

 

4.Other Standard of M classification

 

NF P 92-501: Building materials- Reaction to fire tests, radiation test used for rigid material or flexible materials thickness more than 5mm.

NF P 92-503: Electrical burner test used for flexible materials thickness no more than 5mm

NF P 92-504: speed of spread of flame test used for the materials which are not intended to be glued on a rigid substrate.

NF P 92-505: Dripping test with electrical radiator, used for melting materials.

 

5. NF P 92-503/ NF F 16-101requirement

NF P 92-503: Electrical burner test used for flexible materials thickness no more than 5mm.


Tel: (+0086) 25-8658 3475  Tel: (+0086) 400-666-7290


 Source:防火网  Addtime:12/15/2010 Hits:2760

 Previous: NF F 16-101/NF P 92-501: M classification combustion test

 Next: NF F 16-101/NF X 10-702: Smoke density
 
 
Home | Fire Test & Certification | Standard | News | Product | Exhibition | Flame retardant | On-line consultation | Contact us
Copyright © 2008-2024 Firete.com All Right Reserved
TEL:(+86)-25-8658 3475