Home   Popular Standard   German Standard DIN 5510-2:2009-05
 

German Standard DIN 5510-2:2009-05

German Standard DIN 5510-2:2009-05

 

1. Standard-- DIN 5510-2:2009-05 fire test for railway component

DIN 5510-2: preventive fire protect in railway vehicle parts 2: Fire behaviour and fireside effects of material and parts

 

Effective Date:
This standard since May 1, 2009 entered into force

 

Introduction Date:
Since May 1, 2012, the May 1, 2009 after the development of the vehicle must follow the standards.


Transition period:
Latest from 1 May 2014, the remains can only supply to meet the standards of vehicles.

 

2. Standard Scope -- DIN 5510-2:2009-05 fire test for railway component

This standard applies to vehicle, these vehicles including railway construction and operation of the provisions of (EBO), narrow-gauge railway construction and operating requirements (ESBO), magnetic levitation railway construction and operation of the provisions of (MbBO) and the tram construction and operation requirements (BOSstrab) The effective range. This standard has provided the following objectives:
- The phenomenon of combustion characteristics and burn complicated classification
- Have the necessary test methods
- To prevent fire, on the manufacture of vehicles, materials and components used in the combustion characteristics and burn complicated by the phenomenon of necessary requirements.

 

3. Standard Brief- DIN 5510-2:2009-05 fire test for railway component

DIN 5510-2 determination the fire classification of railway vehicle material and structure by burning buhaviour, smoke density, dropping behaviour and toxic.

 

4. DIN 5510-2 the main concerns:

 

4.1    Reaction to fire

 

4. 1.1.  S1 Fire testing—small switches, armrest, etc, small parts.

Test method: DIN 53438-1DIN 53438-2DIN 53438-3

Classification: S1

 

4. 1.2.  S2-S5 Fire testing—except flooring cover

Test method: Testing of materials, small components and component section for rail vehicles—Determination of burning behavior using a gas burner.

Classification: S2-S5

 

4. 1.3.  Flooring cover fire testing

Test method: EN ISO 9239-1 or DIN 4102-14

Classification: SF1-SF3

Classification

SF1

SF2

SF3

Critical heat flux

2.5KW/m2

2.5KW/m2

4.5KW/m2

Smoke obscuration

No requirement

2500%*min

750%*min

 

4. 1.4.   Seat for fire testing

Test method: DIN EN 1201-1 and DIN EN 1201-2

 

4. 1.5.   Electrical equipment

Test method: DIN EN ISO 4589-2 or DIN EN 60695-11-10

Classification: Oxygen index 28% or 30%

 

4. 1.6.   Cable fire testing

Test method:

EN 50266-2-5:2001: Common test methods for cable under fire condition—Test for vertical flame spread of vertically-mounted bunched wires or cables –Part 2-5: Procedures –Small cables-Category D

DIN EN 60332-1-2:2004 Tests on electric and optical fibre cables under fire conditions—Part 1-2: Test for vertical flame propagation for a single insulated wire or cable.

DIN EN 61034-2: Measurement of smoke density of cables burning under defined conditions---Part 2: Test procedure and requirement.

 

4.2.   Smoke development

Test method: DIN 54837

Classification: Not reached SR1SR1SR2

Not reached SR1: 100(%*min)SR1: 100(%*min)SR2: 50(%*min)

 

4.3.   Droplet

Test method: DIN 54837

Classification: Not reached ST1-ST2

 

4.4.   DIN 5510-2 the main concerns:

FlammabilityS1-S5SF1-SF3

Smoke developmentSR1-SR2

DroppingST1-ST2

Smoke density and toxicity DIN EN 5659-2

Vertical single Cable fire testing DIN EN 60332-1-2

Vertical bunch Cable fire testingDIN EN 50266-2-4 /DIN EN 50266-2-5

Smoke density of cable fire testingDIN EN 61034-2

 

5. DIN 5510-2:2009 the main fire test standard:

DIN 54837

Determination of burning behaviour a gas burner

ISO 9239-1

Reaction to fire tests for flooring

DIN 53438

Testing of small materials

DIN ISO 5659

Smoke density and Toxicity

DIN EN 1021-1

Seat testing

DIN EN 60332-1-2

Vertical single Cable fire testing

DIN EN 50266-2-4

DIN EN 50266-2-5

Vertical bunch Cable fire testing

DIN EN 61034-2

Smoke density of cable fire testing

 

6. Application DIN 5510-2 fire testing materials

Rubber ProductRubber seal

Ceiling Covering

Walling Covering

TextileNon-woven fabrics CurtainCurtainAdumbral Product

Seat shellSeat trim

Flooring CoveringPVC Flooring covering

CableCable tieCable tube

Foam materialSpongeMelamine Foam

PaintAdhesivePigmentVarnish

FRP composite materialsSMC sheet

Braided hoseHose protection

Windowdoor framework

Small parts

ConnectorConnected equipment

pipecorrugate pipeHeating pipeCooling pipe

Other materials

 

(+86) 025-8658 3475 

 


 Source:防火网  Addtime:7/29/2010 Hits:6135

 Previous: USA Standard : NFPA 130:2010

 Next: France Standard NF F 16-101:1988/NF F 16-102:1992
 
 
Home | Fire Test & Certification | Standard | News | Product | Exhibition | Flame retardant | On-line consultation | Contact us
Copyright © 2008-2024 Firete.com All Right Reserved